-- Steady & Reliable Manufacturer --
01 Product Overview
Fire-resistant cables, also termed circuit integrity cables, are designed to maintain electrical circuit functionality for a defined period under direct fire exposure. These cables integrate fire-resistant layers, typically constructed from mica tape wrapped around the conductor. Under high heat, the mica sinters to form a solid, insulating mineral barrier that preserves circuit integrity. This design ensures that critical systems such as emergency lighting, fire pumps, alarms, and smoke extraction fans remain powered during a fire event, facilitating safe evacuation and supporting firefighting operations. The construction is based on established standards like IEC 60331, which define the specific temperature, duration, and mechanical shock requirements for cable performance in fire conditions.
02 Company Profile
Jiangsu Qucheng Cable Technology Co., Ltd. is a manufacturer located in Yixing, Jiangsu—a central hub for cable production in China. Since our establishment in 2018, we have operated a 40,000-square-meter factory equipped with advanced production lines and a comprehensive testing center. Our quality management systems are certified to ISO9001, ISO14001, and ISO45001 standards, and our products hold industry-specific certifications including CB and TÜV. Our manufacturing infrastructure supports the production of fire-resistant cables that comply with international fire safety standards. We export to markets across Southeast Asia and the Middle East, providing cable solutions for critical infrastructure projects that demand stringent safety and reliability requirements.
03 Application Fields
- High-Rise High-rise buildings - Power supply for fire alarm systems, smoke extraction, emergency lighting, and evacuation systems in commercial and residential towers.
- Transport Transportation infrastructure - Airports, railway stations, and subway tunnels require fire-resistant cabling to maintain signaling, communication, and lighting during emergency situations.
- Power Power generation plants - Nuclear and conventional power stations use these cables to maintain control and safety systems during fire-related emergencies.
- Industrial Industrial facilities - Oil refineries, chemical plants, and manufacturing sites where process safety and emergency shutdown systems must remain operational.
- Public Public buildings - Hospitals, schools, and government facilities requiring uninterrupted power to life-safety systems during a fire.
04 Technical Specifications
| Rated Voltage | 0.6/1 kV |
| Conductor Material | Plain annealed copper, Class 2 stranded per IEC 60228 |
| Fire-Resistant Layer | Mica glass tape (single or double layer depending on fire rating) |
| Insulation Material | Cross-linked Polyethylene (XLPE) or Silicone Rubber |
| Inner Sheath | Low Smoke Zero Halogen (LSZH) compound |
| Armour Type | Galvanized Steel Wire Armour (SWA) or Steel Tape Armour (STA) |
| Outer Sheath | LSZH (Low Smoke Zero Halogen) or PVC (ST2) |
| Fire Performance | IEC 60331 (circuit integrity under fire), BS 6387 (Category CWZ) |
| Flame Retardance | IEC 60332-3-24 (flame retardance for bunched cables) |
| Operating Temperature | -40°C to +90°C (normal operation); +950°C for up to 180 minutes (under fire) |
05 Key Features & Core Characteristics
- Integrity Maintains circuit integrity for up to 180 minutes at 950°C per IEC 60331, ensuring critical systems stay operational during evacuation.
- LSZH Low Smoke Zero Halogen sheathing limits smoke emission and eliminates toxic/corrosive gas release, reducing harm to people and equipment.
- Armour Steel wire or tape armour provides mechanical protection against impact, crushing, and rodent damage in demanding installations.
- Flex Stranded copper conductors offer flexibility for routing in cable trays, conduits, and tight spaces without compromising performance.
- Standards Manufactured to IEC, BS, and EN standards, meeting international fire safety requirements for building and infrastructure projects.
- Trace Each cable is marked with batch numbers, enabling full traceability through our production records and quality control documentation.
06 Technical Notes
Our fire-resistant cables are constructed with mica tape wrapped directly over the conductor, followed by XLPE or silicone rubber insulation to provide both fire resistance and electrical insulation properties. The armouring layer (SWA or STA) provides mechanical protection for installations where cables are subject to physical stress. The outer LSZH sheath is formulated to emit minimal smoke and no halogen gases under combustion, as verified by IEC 60754-2 testing. All cables are subjected to routine fire performance testing, including circuit integrity testing at 950°C, flame spread testing, and smoke density measurement. Our production process is digitally monitored through our 5G-based smart manufacturing system, ensuring consistent quality and complete record-keeping for each production batch.
07 Frequently Asked Questions
Furthermore, the company has integrated a 5G-based smart manufacturing system, enabling digital monitoring of the production process and full quality traceability, thereby enhancing efficiency and product consistency. Qucheng Cable is committed to providing safe, reliable, and high-performance cable solutions for global customers.