01 Product Overview

Flame retardant cables are designed to limit the spread of fire along cable pathways and self-extinguish when the ignition source is removed. The flame retardant performance is achieved through the use of insulation and sheathing materials that contain flame retardant additives, which suppress combustion and prevent fire propagation. Key flame retardant standards include IEC 60332-1-2 (single cable vertical flame test), IEC 60332-3-24 (flame spread test for bunched cables), and UL 1685 (vertical tray flame test). These tests evaluate cable performance under different fire exposure conditions, with requirements for flame spread distance, duration of after-flame, and smoke emission. Our flame retardant cables are manufactured with PVC, LSZH, or XLPE materials that meet these standards, ensuring compliance with building codes and safety regulations for public buildings, transportation systems, and industrial facilities.

02 Company Profile

Jiangsu Qucheng Cable Technology Co., Ltd., established in 2018 in Yixing, Jiangsu, operates from a 40,000-square-meter factory with testing facilities capable of performing flame retardance testing in accordance with IEC 60332 and other international standards. We hold ISO9001, ISO14001, ISO45001, CB, and TÜV certifications. Our 5G-based smart manufacturing system ensures consistent material formulation and extrusion parameters for flame retardant cable production. Our flame retardant cables are used in public buildings, mass transit systems, and industrial facilities across Southeast Asia and the Middle East.

03 Application Fields

  • Buildings Public and commercial buildings - Fire safety compliance for electrical installations in hospitals, schools, airports, and shopping centers.
  • Transit Mass transit systems - Tunnels, railway stations, and train carriages where fire spread along cable pathways must be controlled.
  • Industrial Industrial facilities - Manufacturing plants, refineries, and chemical facilities where fire safety regulations require flame retardant cable installations.
  • Data Data centers - Cable tray installations where fire propagation must be limited to protect sensitive equipment.
  • Power Power generation plants - Conventional and renewable power plants requiring flame retardant cables for safety compliance.

04 Technical Specifications

Flame Test Standard IEC 60332-1-2, IEC 60332-3-24, UL 1685 (optional)
Single Cable Test Flame applied for 60 seconds; after-flame duration ≤ 60 seconds; carbonized distance ≤ 50 mm from lower edge
Bunched Cable Test Flame applied for 20 minutes; maximum flame spread ≤ 2.5 meters; after-flame duration ≤ 60 minutes
Smoke Emission Light transmittance ≥ 60% per IEC 61034 (for LSZH cables)
Halogen Content Zero halogen per IEC 60754-2 (for LSZH cables)
Insulation Materials PVC, XLPE, or LSZH (depending on cable type and application)
Sheath Materials PVC, LSZH, or cross-linked polyolefin
Temperature Range -40°C to +90°C (depending on material selection)
Voltage Rating 300/500V to 26/35 kV (depending on cable type)
Standards IEC 60332, BS 4066, EN 50266, UL 1685

05 Key Features & Core Characteristics

  • Flame Flame retardant formulations suppress combustion and prevent fire propagation along cable pathways.
  • Self Cables are designed to self-extinguish when the ignition source is removed, limiting fire damage.
  • Smoke LSZH options provide low smoke emission, maintaining visibility for evacuation during fire events.
  • Halogen Zero-halogen options prevent release of corrosive gases that damage equipment and harm personnel.
  • Comply Manufactured to meet IEC 60332-1-2 and IEC 60332-3-24 flame retardance requirements.
  • Trace Full material traceability ensures consistent flame retardant performance across all production batches.

06 Technical Notes

Flame retardant cables are manufactured using materials with flame retardant additives that suppress combustion through chemical and physical mechanisms. PVC compounds incorporate antimony trioxide and halogenated flame retardants that release halogen radicals to interrupt the combustion chain reaction. LSZH compounds use metal hydroxides (such as aluminum hydroxide or magnesium hydroxide) that release water vapor upon heating, cooling the fire and diluting combustible gases. The flame retardant performance is verified through testing per IEC 60332-1-2 for single cables and IEC 60332-3-24 for bunched cables. Single cable testing involves applying a flame to a vertical cable sample for 60 seconds, with requirements for after-flame duration (≤ 60 seconds) and carbonized distance (≤ 50 mm). Bunched cable testing evaluates the flame spread along a group of cables, with requirements for maximum flame spread distance (≤ 2.5 meters) and after-flame duration (≤ 60 minutes). Our 5G-based smart manufacturing system monitors material formulation and extrusion parameters to ensure consistent flame retardant properties. We recommend consulting building codes and project specifications to determine the required flame retardance category and material selection for each installation.

07 Frequently Asked Questions

Q1 What is the difference between flame retardant and fire resistant cables? +
Flame retardant cables are designed to prevent the spread of fire along cable pathways and self-extinguish when the ignition source is removed. Fire resistant cables (circuit integrity cables) go further: they continue to operate and carry current during a fire. Flame retardance is about limiting fire propagation; fire resistance is about maintaining circuit functionality. Many fire resistant cables also incorporate flame retardant materials, but flame retardant cables do not necessarily offer circuit integrity during fire.
Q2 What is the difference between IEC 60332-1-2 and IEC 60332-3-24 testing? +
IEC 60332-1-2 is a single cable vertical flame test where a flame is applied to a vertical cable sample for 60 seconds. It evaluates whether the cable self-extinguishes and limits flame spread. IEC 60332-3-24 is a bunched cable test where a group of cables is exposed to flame for 20 minutes, evaluating flame spread along the cable bundle. The bunched test is more severe and better represents cable tray installations in buildings, where multiple cables are routed together.
Q3 What materials are used for flame retardant cables? +
PVC (Polyvinyl Chloride) is the most common material for flame retardant cables, containing flame retardant additives such as antimony trioxide. LSZH (Low Smoke Zero Halogen) compounds provide flame retardance through metal hydroxide additives and offer the additional benefits of low smoke and zero halogen emissions. XLPE (Cross-linked Polyethylene) can also be formulated with flame retardant additives. The material selection depends on the application requirements for flame retardance, smoke emission, halogen content, and operating temperature.
Q4 Do flame retardant cables produce toxic smoke? +
Standard flame retardant cables (PVC type) can produce toxic hydrogen chloride gas and dense smoke when burned due to the halogen content in PVC. LSZH flame retardant cables are formulated to emit minimal smoke and no halogen gases, making them safer for enclosed spaces. For applications where toxicity and smoke density are critical concerns, we recommend LSZH flame retardant cables that meet IEC 60754-2 and IEC 61034 requirements.
Q5 What flame retardant standards are required for building installations? +
Building code requirements vary by region and application. In Europe, EN 50575 defines the fire performance classification for cables in construction works, with classes from Eca to Fca. In the UK, BS 5839 requires specific fire performance for fire alarm cables. In the US, UL 1685 and NFPA 262 are commonly referenced. We recommend consulting your local building codes and project specifications to determine the required flame retardance category and material selection for your installation.
Reliable Cable Solutions for Critical Sectors
Jiangsu Qucheng Cable Technology Co., Ltd., established in 2018, is located in Yixing, Jiangsu—a key cable manufacturing hub in China. The company operates a modern factory covering 40,000 square meters, equipped with advanced production lines and a comprehensive testing center. Its main product series include power cables, new energy cables, and electrical equipment cables. The company holds ISO9001, ISO14001, and ISO45001 management system certifications, as well as industry qualifications such as CB and TÜV. Its products are widely used in power grids, photovoltaic and wind power projects, and industrial applications, and are exported to regions including Southeast Asia and the Middle East.
Furthermore, the company has integrated a 5G-based smart manufacturing system, enabling digital monitoring of the production process and full quality traceability, thereby enhancing efficiency and product consistency. Qucheng Cable is committed to providing safe, reliable, and high-performance cable solutions for global customers.
Jiangsu Qucheng Cable Technology Co., Ltd.
How can we help you?

Please fill in the contact form and we will contact you as soon as possible.
Contact form
All fields with * are reqired to fill out
  • Keep me informed

    When you send an inquiry, we will collect your information.

    We process the data you provide to process your inquiry. I agree to the processing of my data and have taken note of further information in the Data Protection Statement.